Scxi-1357. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. Scxi-1357

 
 Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devicesScxi-1357 SCXI-1357 consists of a 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM, and two analog bus plugs for connecting the backplane components

Downloadable Technical Manuals and Datasheets. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. arincSCXI ™ SCXI-1127/1128 User Manual SCXI-1127/1128 User Manual December 2000 Edition Part Number 322149B-01 Worldwide Technical Support and Product Information ni. Leave jumper W1 on the SCXI-1100 in the factory-default (parking) position. ¥Ifyou are using a PXI-1011 use an HV8-BAN4 cable. NI 9269 Getting Started Guide National. comDrives / Motion / Motor Control / Positioning. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. All prices are shown in USD. Show More Description. Add to Cart. MXI / MXI-2 / MXI-3 / MXI-4. com National Instruments Corporate Headquarters 11500 North Mopac Expressway Austin, Texas 78759-3504 USA Tel: 512 794 0100. If you are usingSite Search Results. This document contains information about the NI-DAQmx driver software, which you canCatalog Datasheet MFG & Type PDF Document Tags; bergquist. 1553. To add moreQuick Start Guide Documentation Guide NI 9269 Getting Started Guide National Instruments apexwaves manuals ||| GETTING STARTED GUIDE NI 9269 100 kS/s/ch Simultaneous, 10 V, Isolated, 4-Channel C Series Voltage O. lang:i-klingon score:10 filesize: 525. The cable HV8-BAN4 is used to connect SCXI backplanes to an NI DMM. Using the SCXI-1362. Readers should have a basic knowledge of single module scanning hardware setup and programming. View All (1) 0 Kudos Message 1 of 2 (1,492 Views) Reply. Recorders / DataloggersSite Search Results. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. SCXI-1128. National Instruments SCXI-1129 with electromechanical relays. Play any role in anyway if model of chassis is same . The SCXI kit connects. The NI USB-1357 is designed and manufactured by National Instruments. This enables the SCXI system to be located closer to the sensors and transducers. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. This does not include any cables. ; Page 2 Thailand 662 992 7519, United Kingdom 44 0 1635 523545 For further support information, refer to the Technical Support and Professional Services. Embedded & Industrial . The National Instruments PXI-4021 (Part Number: 778277-01) switching controllers permit the control of SCXI-based switching frameworks from a PCI or PXI slot. 1. Rated 5 /5 based on 15 ratings. Readers should have a basic knowledge of single module scanning hardware setup and programming. The NI SCXI-1343 is another option which is a general-purpose SCXI adapter with screw terminals. This cable is included in the SCXI-1357 and SCXI-1358 multichassis expansion kits. They consist of high-quality,low-noise cables,which guarantee reliable communication and signal integrity at up to 10 m. 1553. 1-slot adapters are sold separately. This document contains information about the NI-DAQmx driver software, which you can also use to program NI switch modules. 59 to the computer. 2 x 6. multiplexer/matrix modules. The SCXI-1357 consists ofa 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backpla ne components. Alternatively, some switch controllers like the NI USB-1359/1358/1357 can connect an NI SCXI switch module directly to a computer. are not included with this equipment unless listed in the above stock item description. following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Some SCXI switches can route analog signals to their rear connector, and you can use the SCXI-1357 to share these signals among several modules in compatible chassis. previous page start next page. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. multiplexer/matrix modules. Ships in 5-10 Days. Right click on Devices and Interfaces and click Create New. arincarinc & 1553 . ni 1357 キット(4 スロット)は次の部品で構成されてます。 • ni usb-1359 またはni scxi-1359 • ni scxi-1359 •8ピンhvab プラグ(1) • sh9md-9md ケーブル(scxi キット)またはusb ケーブル (usb キット) 図1 は、ni 1357/1358/1359 キットに含まれる部品を示します。following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. Recorders / DataloggersEmbedded & Industrial . arincUsing the SCXI-1127 Switch Module National Instruments pg. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. arincNI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. Abstract: No abstract text available Text: inputs is the base of an NPN and a PNP transistor whose base currents are of opposite polarity and , s s s The LT ® 1357 is a high speed, very high slew rate operational amplifier with outstanding , IOS 5kâ ¦ + OUT 1LSB A VOL 1357 TA01. SCXI-1129. DMM,and analog bus plugs for connecting the backplane components. The NI SCXI-1127/1128/1129/1175 modules have the capability to route analog signals to their rear connector. 1553. The SCXI-1357 consists of a 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backplane components. National Instruments SCXI-1357 4-Slot High Voltage Backplane Adaptor. This enables the SCXI system to be located closer to the sensors and transducers. The user can control the modules with the help of these lines. Each cable assembly includes a cable and one or more SCXI cable adapters. arincarinc & 1553 . • Ground the negative lead of the thermocouple inside the SCXI-1300 terminal block, by connecting CH– to CHSGND as shown in Figure 4. SCXI-1357 Home SCXI-1357. In Stock Ships Today: SCXI-1362:multiplexer/matrix modules. 1. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. Switch Module supports the analog bus with a specific adapter, the high-voltage analog bus backplane adapter in the SCXI-1357/1358 kit, at the back of the module. Part Numbers: 776575-571, 776575-572. 07-08-2009 12:42 PM - edited ‎07-08-2009 12:45 PM. These are not necessary, as the SCXI-1130 cannot make use of them. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. In Stock. 2 installation manual online. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. Important Notice: Other accessories, manuals, cables, calibration data, software, etc. The National Instruments PXI-4021 (Part Number: 778277-01) switching controllers permit the control of SCXI-based switching frameworks from a PCI or PXI slot. For example, NI DMMs and NI 4021 switch controllers require an NI SCXI-1359/1358/1357 adapter kit to connect to an NI SCXI switch module. Figure 1. This enables the SCXI system to be located closer to the sensors and transducers. 1553. Quick Start Guide Installation Guide Guide Archived NI 1357 1358 1359 SCXI Controller Adapter Kit Installation Guide National Instruments 374133 324133 Technical Communications 374133c ni support compware manuals ||| INSTALLATION GUIDE NI 1357/1358/1359 SCXITM Controller/Adapter Kit Introduction This document. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. This document describes the components, installation, and configuration. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. The NI PXI-4021 requires no extra programming other than the NI-SWITCH controller it receives with the National Instruments switches. Shakers / Stirrers / MixersNational Instruments Corporation 776575-571 SCXI-1357-01, 4-Slot High-Voltage Backplane with cables For use with the SCXI-1127. Visit ni. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. The SCXI-1358 consists of (2) 1-slot HVAB Adapters, (1) SCXI-1359 2-slot HVAB Adapter and (1) 8-Slot HVAB Adapter. a. 1553. arincarinc & 1553 . 1553. Menu. The basic backplane is offered under the part number 776575-57, while the additional kit part numbers include aQuick Start Guide Installation Guide Guide Archived NI 1357 1358 1359 SCXI Controller Adapter Kit Installation Guide National Instruments 374133 324133 Technical Communications 374133c ni support compware manuals ||| INSTALLATION GUIDE NI 1357/1358/1359 SCXITM Controller/Adapter Kit Introduction This document describes. 1-slot adapters are sold separately. Using the SCXI-1362. flathead screwdriver Long-nose pliers Wire cutter Wire insulation stripper Safety Information Cautions Do not operate the device in an explosive atmosphere or where there may be flammable gases or fumes. We have New & Used SCXI-1357 Adapter Board by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National. Alternatively, a switch controller installed in the rightmost PXI slot of anPage 2 SCXI Controller/Adapter Kit ™ This document describes the components, installation, and configuration of the National Instruments SCXI-1357/1358/1359 and the NI USB-1357/1358/1359 controller/adapter kits. True-rms value of a signal. arincarinc & 1553 . Fig. SCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. Alternatively, a switch controller installed in the. Answer: SCXI-1357 National Instruments This is a problem with the NI-DAQmx8. 776572-93 Summary: 776572-93 from National Instruments is National Instruments 776572-93 SCXI-1193 500 MHZ MuLTIPLEXER Details. 1553. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. The cable assembly connects to the front-end signal conditioning SXCI. Catalog Datasheet MFG & Type PDF Document Tags; 1994 - Not Available. Each cable assembly includes a cable and one or more SCXI cable adapters. PXI-4070, NI 4021 SCXI-13573, SCXI-13583, SCXI-13624 Shielded Internal5 or External6 Internal5 or erxternal6 PCI-6534 PXI-6534 SCXI-1355 Shielded N/A N/A 1Requires no external cabling. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. National Instruments manufactured this High Voltage Backplane. 2. We currently maintain an inventory with a wide array of components. the SCXI 1357 high voltage backplane. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. Show More Description. Find the National Instruments SCXI-1000 at our website: Click HERE. Email: info@artisantg. Single module information can be found in the NI. Contact a sales representative for a quote. Combining this 1-slot HVAB Adaptor with another 1-slot Adaptor creates and an SCXI-1359 2-slot HVAB create an SCXI-1357. The SCXI 1325 is a screw terminal block that has 26 terminals for signal connections to the SCXI 1124 module. Proceedings of the 2003 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2003, American Society for Engine ering EducationNational Instruments PXI-4021 Switch ControllerPart Number: 184793G-02, 778277-01NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. ANE ASSEMBLY KIT 1 M CABLE SCXI-1357-01 4-SLOT HIGHVOLTAGE BACKPLANE CABLE ASSY,SCXI-1127,1M NI USB-1357 HIGH VOLTAGE BACKPLANE ASSEMBLY KIT 1 M CABLE SCXI-1357-02 4-SLOT HIGHVOLTAGE BACKPLANE. SCXI-1357 (4-Slot) (See Figure 6) We have New & Used SCXI-1357 Adapter Board by National Instruments In Stock & ready to ship! Request a fast quote or call 1-800-915-6216 now to get your price on all National Instruments models. If you want to share these signals among several modules, you need to use the high-voltage analog bus (HVAB) adapter (like the SCXI-1357 and SCXI-1358). multiplexer/matrix modules. Single module information can be found in the NI. SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. To add moreSCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. Single module information can be found in the NI. tor backshell kit to ensure that the terminals are not accessible. The NI USB-1357 is designed and manufactured by National Instruments. Single module information can be found in the NI. National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. This controller is especially useful in production tests where you need an SCXI controller to route signals through a switch to existing data acquisition devices. Phone: (217) 352-9330. The SCXI-1357 consists ofa 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backpla ne components. Around 80% of the collection are research articles published in journals, 6% are papers from conference proceedings, 5% are book chapters, the rest are other types of documents. Finally, there is the SCXI-1355, which is a shielded cable assembly with cable lengths to. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. Refer to page 507 for more information on switch cabling. 009" 8. Menu. SCXI-1129. . Part Number: 776575-581, 776575-582. Control Unit I/O Systems Controller Computer Hardware Measuring Instruments. The high voltage backplane has the following specifications: I have combo chassis 1050 with DMM 4070 placed on the last position to communicate with SCXI module through D9 connector to PXI-1357 my issue is that The NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. Ensure the DAQ (Data AQuisition) device used to connect to SCXI Chassis is recognized by NI-MAX and self-test has passed succesfully. This module has the following. Product support for AXIS P1357 Network. NI USB-1357/1358/1359 controller/adapter kits. For example, in a 2-wire 32×1 multiplexer, two NI SCXI-1127/1128 modules can create a 64×1 2-wire multiplexer with an NI SCXI-1359. 57 to 0. NI SCXI cable assemblies connect a DAQ device to the SCXI system. For SCXI systems operating in multiplexed mode, you need onlyNational Instruments offers switches with scanning capabilities. Each cable assembly includes a cable and one or more SCXI cable adapters. 1553. Alternatively, a switch controller installed in the. The 9 Pin DIN connectors for the SH9MD-AUX cable are circled in the Figure 5. 18 185434-0R18The SCXI-1129 is warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. If your switch module cannot connect to the SCXI-1357 then you can use the SCXI-1362 Adapter Kit to connect to your DMM. Proceedings of the 2003 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2003, American Society for Engine ering EducationNational Instruments offers switches with scanning capabilities. 7. Other slot adapters are sold separately. The cable HV8-BAN4 is used to connect SCXI backplanes to an NI DMM. 1 shows a pi cture of the actual system. Page 2 SCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01. arincSCXI-1127/1128, SCXI-116X family, and SCXI-1190/1191. NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. Manufacturer. 1 Data Acquisi tion System Set-upSCXI-1327 Installation Guide 6 ni. Each cable adaptor has a 50-pin male breakout. Tags: SCXI1001. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For. It consists of a data acquisition board (PCI-MIO-16E- 4), terminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital-to-analog conversion module. arincFind many great new & used options and get the best deals for Hipotronics HV10 High Voltage Megohmmeter at the best online prices at eBay! Free shipping for many products!arinc & 1553 . This does not include any cables. MXI / MXI-2 / MXI-3 / MXI-4. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. Readers should have a basic knowledge of single module scanning hardware setup and programming. To add moreNational Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThe 185003A-01 is the 1-slot HVAB Adapter for SCXI chassis. 61 K page_count: 67 document date: 2009-04-24 The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. To connect your NI 4060 to SCXI scanners and matrices, special cable kits are available (SCXI-1357 and SCXI-1358). Each cable assembly includes a cable and one or more SCXI cable adapters. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. The SCXI-1357 can be used with and AUX cable to let the DMM control the SCXI chassis and send the trigger to the SCXI switch. com333 Product Name Right. The SCXI-1129 by National Instruments is In Stock & Ready to Ship. 1553. Experienced Expert Engineers that specialize in your applicationThe three available backplane kits are: SCXI-1357, SCXI-1358, and or SCXI-1359. The SCXI-1358 is identical to the SCXI-1357, except it is for a 12-slot SCXI chassis. The rear filler panel is developed to cover slots that remain unoccupied by multi-chassis adapters, cable assemblies, the SCXI-1357/SCXI-1358 backplane units, or cable extenders. Triggering for Switches (NI 4060 only)NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. tor backshell kit to ensure that the terminals are not accessible. National Instruments offers switches with scanning capabilities. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. 1-slot adapters are sold separately. Other Industrial. Alternatively, a switch controller installed in the. Abstract: D412 SP400 ASTM D2240, D412 ASTM D374 D1458 D149 D150 D2240 D257 Text: Number 0. General. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. The SCXI-1357 can be used with and AUX cable to let the DMM control the SCXI chassis and send the trigger to the. Add to Cart. This enables the SCXI system to be located closer to the sensors and transducers. arinc & 1553 . Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. Associated Part Numbers: 184366-01, 184366C-01, 184366D-01, 184366E-01, 776572-27. The AUX connector is meant to be used when a DMM is controlling a switch in an SCXI Chassis, like out SCXI-1130. MXI / MXI-2 / MXI-3 / MXI-4. arinc & 1553 . Alternatively, a switch controller installed in the. Components of the NI 1357/1358/1359 Controller/Adapter Kit Installing the KitTengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. 009 0. The cable assembly connects to the front -end signal conditioning SXCI. C. Readers should have a basic knowledge of single module scanning hardware setup and programming. Bruel & Kjaer JJ 2614 Input Adapter. The NI 4021 is compatible with the SCXI-1357/1358 high-voltage backplane adapters and the SCXI-1362 low-voltage adapter. One SCXI cable assembly per SCXI chassis is needed to operate the SCXI system in multiplexed mode. Site Search Results. PXI-2503, SCXI-1127, SCXI-1128, or SCXI-1129, you can measure thousands of channels, consisting of voltages, thermocouples, RTDs,. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Fig. National Instruments SCXI-1359 2-Slot High Voltage Backplane Adaptor. The SCXI-1362 works much like the SCXI. You can add insulation or padding if necessary. Menu. If necessary, power on the chassis. These Controllers are also compatible with the low-voltage adapters like the SCXI-1362. Shakers / Stirrers / Mixersarinc & 1553 . The PCI-GPIB board was not made to control an SCXI chassis. SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. General. The probe sets meet IEC 1010 safety requirements and permit direct probing of circuits and cables. This enables the SCXI system to be located closer to the sensors and transducers. It is possible to exit the trigger DMM full measure to the socket at the front of the DMM. NI SCXI-1357/1358/1359 kit, proceed directly to step 4 to create a new SCXI chassis. This cable assembly routes signals from the digitizer to subsequent SCXI chassis. The NI USB-1357 is used with the NI driver tools. The NI 1359 and SCXI-1362 communication adapters provide the interface to your chassis through a• Combination chassis for SCXI and PXI/Compact PCI modules • House all SCXI modules Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. Work with our experts to sustain your critical applications. The high voltage backplane has the following specifications: This enables the SCXI system to be located closer to the sensors and transducers. arincThen, follow the steps below: 1. previous page start next page. Part Number: 776575-57, 185006A-01, 185006B-01. arincSCXI-1314 Printed Circuit Board Diagram The following illustration shows the locations of the SCA and SCB resistors, the quarter-bridge resistors, and channels 0 through 7 of the SCXI-1314 terminal block. Buy It Now. Each cable adaptor has a 50-pin male breakout connector for attaching additional DAQ devices. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01National Instruments 181625-01 Rear Filler Panel for SCXI-1361. This Backplane Assembly is used for matrix expansion or signal routing between SCXI modules. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. National Instruments ¥ Tel: (800) 433-3488 ¥ Fax: (512) 683-9300 ¥ info@ni. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. arincarinc & 1553 . Modules like the SCXI-1127, 1128, 1129, and 1175 are able to connect to the HVAB, so those would be more appropriate for the SCXI-1357 (4-slot adapter) or SCXI-1358 (12-slot adapter). Homepage;NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Tengo un NI 4070 digital multi-meter(DMM) con 2 chassis controlando módulos Switch. Fast Quotes & Shipping. 1-slot adapters are sold separately. Alternatively, a switch controller installed in the rightmost PXI slot of an NI PXI-1010/1011/1050/1052 chassis does not require any additional cables or adapters to connect to the switch module. Proceeding in this direction requires you to create an SCXI controller out of the PCI-GPIB board (or whatever hardware is hot-wired to the SH9MD-AUX cable). National Instruments offers switches with scanning capabilities. 1553. Switches. Combining this 2-slot HVAB Adaptor with (2) 1-slot Adaptor creates an SCXI-1357. following kits: SCXI-1357, SCXI-1358, SCXI-1359, and SCXI-1362. You can also use this cable to cascade digital control signals between multiple SCXI chassis. Choosing a Switch. Run the signal wires through the strain-relief opening. Figure 5: Rear view of SCXI backplanes with 9-pin Din Connectors SCXI switches require a backplane to connect the SH9MD-AUX cable for controlling or triggering. Particle Sizers / Countersabstract: pci-4060 pxi-4060 scxi-1357 4060 pxi-2501 pxi-2503 scxi-1127 scxi-1128 scxi-1129 Text: 4060 hardware, P -1 probe set, NI-DMM, DMM Soft Front Panel, and calibration certificate. The basic backplane is offered under the part number 776575-57, while the additional kit part numbers include a SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. SCXI ™ SCXI-1127 User Manual 32-Channel High-Voltage Multiplexer/Matrix Module SCXI-1127 User Manual January 1999 Edition Part Number 322149A-01 Internet Support E-mail: [email protected][email protected]The National Instruments SCXI-1359 kit includes the NI SCXI-1357 high-voltage 2-slot backplane adapter and cable that connects the digital control lines of NI 407x DMMs, NI 4060 DMMs, or NI 4021 switch controllers to the SCXI-1127, SCXI-1128, SCXI-1129, SCXI-1130, SCXI-1166, SCXI-1167, and SCXI-1193 switch modules. The National Instruments 1357,1358,1359 and SCXI-1362 communication adapters and high-voltage backplane assemblies provide several options for communication with and expansion ofthe functionality ofyour SCXI switch chassis. These modules support the analog bus through a special adapter, the high-voltage analog bus (HVAB) backplane adapter in the SCXI-1357/1358 kit, at the rear of the module. ¿Podría usar un sólo 4070 (o cualquier otro DMM) para controlar los switches en ambos chassis?SCXI™ Switch Modules This document explains how to install, configure, and set up a National Instruments SCXI switch module. com ¥ ni. 1 Data Acquisi tion System Set-upFind the National Instruments SCXI-1001 at our website: Click HERE. † For devices cabled to an NI USB-1357/1358/1359 kit, where the NI USB-1359 is auto-detected and the chassis is auto-created in MAX as shown in Figure 10, complete the following steps. The probe sets meet IEC 1010 safety requirements and permitSCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. 8. 5 bath property. Figure 1. National Instruments 185003A-01 1-Slot High Voltage Backplane AdaptorThis unit is sealed in the manufacturer's bag. ¥Ifyou are using a PXI-1010 or an SCXI chassis use an SCXI-1357 or SCXI-1359 kit. The NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. Includes backplane, AUX-AUX cable, and DMM to AUX cable (1 m) technical specifications at TestMart. This document explains the different scanning options, hardware setup, and programming techniques for scanning several modules. The USB-1357 is a high-voltage SCXI Plug-and-Play Backplane for USB. Fig. View online (12 pages) or download PDF (1 MB) National Instruments SCXI NI 1359, SCXI NI 1358 Installation manual • SCXI NI 1359, SCXI NI 1358 PDF manual download and more National Instruments online manualsThe SCXI-1357 is a National Instruments Adapter Board with a Features Multiple SCXI Cables / Adapters . NI SCXI switch modules require a dedicated switch controller, often cabled to the switch module using an adapter kit. Reinstall the top cover and tighten the top cover screws. Best Offer:SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. Your NI SCXI switch module ships with the NI-SWITCH instrument driver, which you can use to program the device. Alternatively, a switch controller installed in the rightmost PXI slot of anNI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. arincSite Search Results. Sci-Hub collected a database of 88,343,822 research documents, freely available for download. HV8 to HV8 Use this cable to cascade high-voltage 1 185437-01 Cable (Figure 11) analog buses between two SCXI chassis. com for information on these kits. 1553. The AUX connector is meant to be used when a DMM is controlling a switch in an SCXI Chassis, like out SCXI-1130. Particle Sizers / CountersSite Search Results. Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. Alternatively, a switch controller installed in the rightmost PXI slot of anThe PCI-4021 / PXI-4021 control switch devices such as SCXI-1102/B/C, SCXI-1124, SCXI-1127/1128, SCXI-116X family, and SCXI 1190/1191. 若您的switch模块不能够被连接到scxi-1357,那么您可以采用scxi-1362适配工具来连接您的dmm。scxi-1362的工作方式与scxi-1357很像,也采用aux i/o端口来连接dmm的数字信号。能够与scxi-1362配合使用的switch包括: scxi-1160 ; scxi-1161 ; scxi-1163r ; scxi-1190 ; scxi-1191 ; scxi-1192 National Instruments SCXI-1349 Adapter Board. Part Number: 776575-57, 185006A-01, 185006B-01, 185008A-01, 185008B-01 National Instruments 181625-01 Rear Filler Panel for SCXI-1361. 1 shows a pi cture of the actual system. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. arincNI 4021 switch controllers require an NI SCXI-1359/1358/1357 adapter kit to connect to an NI SCXI switch module. The following figure represents the front view of a 2-slot backplane adapter/controller. This model can easily control many switching modules, which includes the following: the SCXI-1102/B/C, SCXI-1124, the SCXI-116X family, the SCXI 1190/1191, and the SCXI. com DAQmx USB was unexpectedly terminated while. 1553. National Instruments will, at its option, repair or replace equipment that proves to be defective duringtheterminal blocks (SCXI 1303 and SCXI 1325), signal conditioning hardware (SCXI 1102), and a digital to analog conversion module (SCXI 1124). Alternatively, a switch controller installed in the rightmost PXI slot of anAll Other NI SCXI. com333 Product Name Right. Work with our. The SCXI kit connects a switch controller to an SCXI switch module; the USB kit connects a computer to an SCXI switch module. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. scxi-1357的安装指南中有一个部分专门介绍怎样将它安装到pxi混合机箱中。 最关键的部分就是通过辅助电缆将DMM的AUX I/O端口连接到SCXI-1357背板连接器的AUX I/O端口上。 SCXI-1194; SCXI-1195; The key component is the auxiliary cable which connects the AUX I/O port of the DMM to the AUX I/O port of the SCXI-1357 backplane connector. BAN4 to LV6 cable Use this cable to connect theTB-2605 0. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. Fraction Collectors / Autosamplers / Autoinjectors / Autowashers / Synthesizers. SCXI-1314 Shunt-Calibration Resistors and Quarter-Bridge Resistors R1 RPJ R2 R3 UJ SCB SCB SCB SCB SCA SCA SCA SCA QTR QTR. 18 185434-0R18The SCXI-1357 consists of a 4-slot high-voltage backplane, two cables for routing analog and digital signals to an external scanning DMM,and analog bus plugs for connecting the backplane components. ni scxiスイッチモジュールにはni-switch 計測器ドライバ が同梱されており、このドライバはデバイスのプログラミングに使用します。 このドキュメントには、NI スイッチモジュールのプログラミングにも使用できるNI-SCXI-1357 Controller module SCXI-1357 Controller module Module Clips Drive controller servo motor Contact: Mr. Triggering for Switches (NI 4060 only)NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. lang:i-klingon score:10 filesize: 525. info@artisantg. Ensure the cable between SCXI chassis and DAQ devices is propperly connected or try another else cable assembly. Fig. Read More Read Less. Refer to the . arincSite Search Results. SCXI-1317 Terminal Block Installation Guide 6 ni. The SCXI-1359 is the 2-slot HVAB Adapter for SCXI chassis. The SCXI-1357, crafted by National Instruments, is a High Voltage Backplane Adapter. NI SCXI-1600 when used with NI SCXI-1349 and either SH68-68-EPM (NI E Series or mass-terminated NI USB M Series) or SHC68-68-EPM (NI M Series) SCXI-1163R SCXI-1190 Note Some switch controllers, like the NI USB-1357/1358/1359, can connect an NI SCXI switch module directly to a computer. The cable assembly connects to the front-end signal conditioning SXCI. 1 Data Acquisi tion System Set-upSCXI ™ SCXI-1129 User Manual 256 Crosspoint High-Density Matrix SCXI-1129 User Manual February 2001 Edition Part Number 322740A-01 Support Worldwide Technical Support and Product Information ni. The high voltage backplane has the following specifications:Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high-voltage backplane. The NI SCXI-1357 is manufactured with part numbers 776575-57, 776575-571 , 776575-572, and 185008B-01. • Combination chassis for SCXI and PXI/Compact PCI modules • House all SCXI modules Assembling the system requires the use of the SCXI 1349 shielded cable assembly and the SCXI 1357 high voltage backplane. The cable assembly connects to the front-end signal conditioning SXCI. Expand the NI-DAQmx Devices tab. HV8 connectors on the adapters allow you to easily route these signals to a DMM, such as the NI 4060/4070, for. Right-click the chassis and choose. If you are using NI-DAQmx to configure SCXI switch modules cabled to an NI USB-1357/1358/1359 kit and the NI USB-1359 is auto-detected and the chassis is auto-created in MAX, expand the NI-DAQmx Devices tab, right-click the chassis, and choose Properties. Fieldpoint / CompactFieldpointThe NI 1357 kit (4 slots) consists of the following components: † NI USB-1359 or NI SCXI-1359 † NI SCXI-1359 † One 8-pin HVAB plug † SH9MD-9MD cable (SCXI kits) or USB cable (USB kits) Figure 1 illustrates the components of the NI 1357/1358/1359 kit. National Instruments NI SCXI 1357 ; National Instruments CompactRIO sbRIO-9603 ; National Instruments Categories.